2025-06-14 06:01 |
详细记录
|
2025-06-14 06:01 |
详细记录
|
2025-06-12 08:40 |
Irradiation tests of the OBDTv1 board at CHARM
/ CMS DT Collaboration
The CMS Muon Drift Tube (DT) chambers require an upgrade oftheir on-detector electronics for operation in the High LuminosityLHC (HL-LHC) due to increased radiation, occupancy and triggerrates. The new On-Detector Board for Drift Tubes (OBDT) digitizesdrift signals with a resolution of 0.8 ns and transmits them viahigh-speed optical links into the counting room, where the fulldetector information will be available to perform the trigger andevent building logic. [...]
2025 - 15 p.
- Published in : JINST 20 (2025) T05009
Fulltext: PDF;
|
详细记录
|
2025-06-12 08:40 |
Safety at HL-LHC IT String during construction, commissioning, and operation
/ Bozzini, D (CERN) ; Bajko, M (CERN) ; Ballarino, A (CERN) ; Blanchard, S (CERN) ; Gascon, J (CERN) ; Heredia, N (CERN) ; Onufrena, A (CERN) ; Perin, A (CERN) ; Rodriguez Mateos, F (CERN) ; Yammine, S (CERN) et al.
The HL-LHC IT String, a test facility for the major components of the HL-LHC Inner Triplet, is currently in its construction and commissioning phases in a surface building at CERN. The primary motivation of the HL-LHC IT String is to study and validate the collective behaviour of its different subsystems which include mainly: the inner triplet superconducting magnets and their correctors, a novel superconducting link, the cryogenics infrastructure for the cooling and quench recovery, the powering and quench protection systems, and the remote alignment system. [...]
2025 - 6 p.
- Published in : IOP Conf. Ser. Mater. Sci. Eng. 1327 (2025) 012189
Fulltext: PDF;
In : 26th International Cryogenic Engineering Conference and International Cryogenic Materials Conference 2024, Geneva, Switzerland, 22 - 26 July 2024, pp.012189
|
详细记录
|
2025-06-12 08:40 |
详细记录
|
2025-06-11 04:16 |
On the improved performances of FLUKA v4-4.0 in out-of-field proton dosimetry
/ Şerban, Alexandra-Gabriela (CERN ; Bucharest U. ; Bucharest, IFIN-HH) ; González, Juan Alejandro de la Torre (Granada U. ; Unlisted, ES) ; Anguiano, Marta (Granada U. ; Unlisted, ES) ; Lallena, Antonio M. (Granada U. ; Unlisted, ES) ; Salvat-Pujol, Francesc (CERN)
A new model for the nuclear elastic scattering of protons below 250 MeV has been recently included in FLUKA v4-4.0, motivated by the evaluation of radiation effects in electronics. Nonetheless, proton nuclear elastic scattering plays a significant role also in proton dosimetry applications, for which the new model necessitated an explicit validation. [...]
arXiv:2412.18314.-
2025-06-02 - 19 p.
- Published in : Radiat. Phys. Chem. 237 (2025) 112947
Fulltext: 2412.18314 - PDF; document - PDF;
|
详细记录
|
2025-06-08 06:03 |
Access to diagnostic imaging and radiotherapy technologies for patients with cancer in the Baltic countries, eastern Europe, central Asia, and the Caucasus: a comprehensive analysis
/ Dosanjh, Manjit (Oxford U. ; Unlisted, US) ; Gershan, Vesna (IAEA, Vienna) ; Wendling, Eugenia C (Unlisted, US) ; Khader, Jamal S (Unlisted, JO) ; Ige, Taofeeq A (Unlisted, NG) ; Ristova, Mimoza (Skopje U.) ; Hugtenburg, Richard (Swansea U. (main)) ; Georgieva, Petya (CERN) ; Coleman, C Norman (Unlisted, US) ; Pistenmaa, David A (Unlisted, US) et al.
Only 10–40% of patients with cancer in low-income and middle-income countries were able to access
curative or palliative radiotherapy in 2015. We aimed to assess the current status of diagnostic imaging and
radiotherapy services in the Baltic countries, eastern Europe, central Asia, and the Caucasus by collecting and
analysing local data..
2024 - 9 p.
- Published in : Lancet Oncology 25 (2024) 1487-1495
publication: PDF;
|
详细记录
|
2025-06-06 09:30 |
Study on discharge and short circuit generation in CMS GE1/1 triple-GEM detectors during Run 3
/ CMS GEM Group of the Collaboration
The installation of the new GE1/1 station of Gas ElectronMultiplier (GEM) detectors in the Compact Muon Solenoid (CMS)experiment was completed during the Long Shutdown 2 (LS2) phase ofthe Large Hadron Collider (LHC). The GE1/1 station has beenoperational in the CMS detector since the beginning of the Run-3data-taking phase, and for the first time the GEM technology wasdeployed on a large scale, comprised of 144 chambers and tested inrunning conditions as integral part of the CMS data acquisition,reconstruction, and analysis chain. [...]
2025 - 37 p.
- Published in : JINST 20 (2025) P05035
Fulltext: PDF;
|
详细记录
|
2025-06-06 06:37 |
Effects of <math display="inline"><mrow><msup><mrow><mi mathvariant="normal">H</mi></mrow><mrow><mo>−</mo></mrow></msup></mrow></math> low beam irradiation and high field pulsing tests in different metals
/ Serafim, C. (CERN ; Helsinki U.) ; Calatroni, S. (CERN) ; Djurabekova, F. (Helsinki U.) ; Peacock, R. (CERN) ; Bjelland, V. (CERN ; Norwegian U. Sci. Tech.) ; Perez-Fontenla, A.T. (CERN) ; Wuensch, W. (CERN) ; Grudiev, A. (CERN) ; Sgobba, S. (CERN) ; Lombardi, A. (CERN) et al.
This work studies the suitability of a set of different materials for manufacturing of more efficient and durable Radio-Frequency Quadrupole (RFQ) structures compared to that currently used in many linear particle accelerators, traditionally made out of copper. RFQs are susceptible to vacuum breakdowns caused by the exposure to high electric fields, resulting in surface degradation. [...]
arXiv:2409.19698.-
2025-01-01 - 14 p.
- Published in : Phys. Rev. Accel. Beams 28 (2025) 013101
Fulltext: PDF;
|
详细记录
|
2025-06-05 09:28 |
The impact of thermal–hydraulic variation on tunnel long-term performance: a tale of two tunnels
/ Wang, Chao (University Coll., Cork ; University Coll., Dublin) ; Xiao, Zhipeng (University Coll., Cork ; CERN) ; Di Murro, Vanessa (CERN) ; Osborne, John (CERN) ; Friedman, Miles (CERN) ; Li, Zili (University Coll., Cork ; University Coll., Dublin)
Long-term structural performance of ageing tunnels is influenced by various natural and anthropogenic factors. This study examines the impacts of two rarely investigated climatic factors: rainfall and temperature [...]
2024 - 17 p.
- Published in : 10.1680/jgeot.23.00074
|
详细记录
|
|
|
|